Product data sheetheatpumpdatabase.com

Shenling ThermaX Pro
Model code: HPM-V120W/R3-C
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
4.54–14.85 kW
COP
5.3
A7/W35
Max flow temp
75°C
Sound power
59 dB(A)
Refrigerant
R290
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 4.54–14.85 kW |
| Max heating output (low temp) | 11.65 kW at A-7/W55 |
| COP (heating) | 5.3 at A7/W35 |
| Operating range (air) | -25 to 45 °C |
| Heating flow temperature | 25–75 °C |
| Cooling performance | |
| Cooling capacity | 12.4 kW |
| Max cooling output (high temp) | 12.4 kW at A35/W18 |
| Cooling flow temperature | 5–25 °C |
| Electrical, acoustic and physical | |
| Power input | 9.5 kW |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 59 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1100 × 1350 × 560 mm |
| Operational Weight | 230 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.