Product data sheetheatpumpdatabase.com

Sime 016T
Model code: SHP-M-PRO-016T
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
18.6 kW
SCOP
4.84
W35
COP
4.5
A7/W35
Max flow temp
65°C
Sound power
72 dB(A)
Refrigerant
R32
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: MCS HP0326/09
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
✓ MCS listed
Certificate: SHP M PRO 016
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 18.6 kW |
| Max heating output (low temp) | 16 kW at A7/W35 |
| COP (heating) | 4.5 at A7/W35 |
| SCOP (heating) | 4.84 at W35 |
| Heating flow temperature | up to 65 °C |
| Cooling performance | |
| Cooling capacity | 16.51 kW |
| Max cooling output (high temp) | 16.01 kW at A35/W7 |
| EER (cooling) | 2.9 at A35/W7 |
| SEER (cooling) | 5.11 at W7 |
| Electrical, acoustic and physical | |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 72 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 523 × 656 × 1040 mm |
| Operational Weight | 120 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.