Product data sheetheatpumpdatabase.com

SolarEast BLN Series
Model code: BLN-010TB3
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
4.2–12.2 kW
COP
4.24
A7/W35
Max flow temp
60°C
Refrigerant
R32
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: MCS HP0303/05
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
✓ MCS listed
Certificate: MCS HP0303/05
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 4.2–12.2 kW |
| Max heating output (low temp) | 11.2 kW at A7/W55 |
| COP (heating) | 4.24 at A7/W35 |
| Operating range (air) | -25 to 45 °C |
| Heating flow temperature | up to 60 °C |
| Cooling performance | |
| Cooling capacity | 10.3 kW |
| Max cooling output (high temp) | 10.3 kW at A35/W7 |
| EER (cooling) | 3 at A35/W7 |
| Cooling flow temperature | 7–12 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 380-415V (Three Phase) |
| Dimensions (H×W×D) | 850 × 1100 × 445 mm |
| Operational Weight | 107 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.