Product data sheetheatpumpdatabase.com

SPRSUN R290 Greenergy Evo Air
Model code: CGK040V4P-A
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
5.52–12 kW
SCOP
5.03
W35
COP
4.48
A7/W35
Max flow temp
70°C
Sound power
52 dB(A)
Refrigerant
R290
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 5.52–12 kW |
| Max heating output (low temp) | 11.2 kW at A7/W45 |
| COP (heating) | 4.48 at A7/W35 |
| SCOP (heating) | 5.03 at W35 |
| Heating flow temperature | 10–70 °C |
| Cooling performance | |
| Cooling capacity | 10.6 kW |
| Max cooling output (high temp) | 9.4 kW at A35/W7 |
| EER (cooling) | 2.95 at A35/W7 |
| Cooling flow temperature | 12–30 °C |
| Electrical, acoustic and physical | |
| Power input | 5.05 kW |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 52 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 960 × 1110 × 475 mm |
| Operational Weight | 125 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.