Product data sheetheatpumpdatabase.com

Stiebel Eltron WPL-A 07 HK Premium 230V
Model code: 200123
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
6.87 kW
SCOP
4.88
W35
COP
5.42
A7/W35
Max flow temp
75°C
Sound power
48 dB(A)
Refrigerant
R454C
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: 011-1W0393_02
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
✓ MCS listed
Certificate: 011-1W0393_02
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R454C |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 6.87 kW |
| Max heating output (low temp) | 4.3 kW at A2/W35 |
| COP (heating) | 5.42 at A7/W35 |
| SCOP (heating) | 4.88 at W35 |
| Operating range (air) | -25 to 40 °C |
| Heating flow temperature | up to 75 °C |
| Cooling performance | |
| Cooling capacity | 10.15 kW |
| Max cooling output (high temp) | 7.3 kW at A35/W7 |
| EER (cooling) | 2.35 at A35/W7 |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 48 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 900 × 1270 × 593 mm |
| Operational Weight | 135 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.