Product data sheetheatpumpdatabase.com

Swegon MU Echos A LC
Model code: MU Echos A LC 19
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
17 kW
COP
3.25
W-5/W45
Max flow temp
54°C
Sound power
62 dB(A)
Refrigerant
R410A
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R410A |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 17 kW |
| Max heating output (low temp) | 17 kW at A-5/W45 |
| COP (heating) | 3.25 at W-5/W45 |
| Heating flow temperature | 25–54 °C |
| Cooling performance | |
| Cooling capacity | 15.5 kW |
| Max cooling output (high temp) | 15.5 kW at A50/W7 |
| EER (cooling) | 2.99 at A35/W7 |
| Electrical, acoustic and physical | |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 62 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 671 × 507 × 537 mm |
| Operational Weight | 100 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.