← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Swegon MU Echos A LC

Model code: MU Echos A LC 22
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
19.6 kW
COP
3.2
W-5/W45
Max flow temp
54°C
Sound power
69 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR410A
ModeHeating & cooling
Heating performance
Heating capacity19.6 kW
Max heating output (low temp)19.6 kW at A-5/W45
COP (heating)3.2 at W-5/W45
Heating flow temperature25–54 °C
Cooling performance
Cooling capacity18 kW
Max cooling output (high temp)18 kW at A50/W7
EER (cooling)2.94 at A35/W7
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level69 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)671 × 507 × 537 mm
Operational Weight104 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.