Product data sheetheatpumpdatabase.com

Swegon TAU Sky Hi HP
Model code: TAU Sky Hi HP 6
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
6.5 kW
SCOP
4.74
W35
COP
4.7
A7/W45
Max flow temp
60°C
Sound power
52 dB(A)
Refrigerant
R32
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 6.5 kW |
| Max heating output (low temp) | 6.5 kW at A7/W45 |
| COP (heating) | 4.7 at A7/W45 |
| SCOP (heating) | 4.74 at W35 |
| Operating range (air) | from -15 °C |
| Heating flow temperature | up to 60 °C |
| Cooling performance | |
| Cooling capacity | 5.4 kW |
| Max cooling output (high temp) | 5.4 kW at A35/W7 |
| EER (cooling) | 3.34 at A35/W7 |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 52 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 700 × 1010 × 370 mm |
| Operational Weight | 67 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.