← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Thermia Atlas

Model code: Atlas 12
Ground Source (GSHP)ResidentialHeating only
Heating capacity
3–12 kW
SCOP
5.86
W35
COP
4.75
B0/W35
Max flow temp
65°C
Sound power
33 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeGround Source (GSHP)
ApplicationResidential
RefrigerantR410A
ModeHeating only
Heating performance
Heating capacity3–12 kW
COP (heating)4.75 at B0/W35
SCOP (heating)5.86 at W35
Heating flow temperature20–65 °C
Electrical, acoustic and physical
Power input13.5 kW
Electrical supply380-415V (Three Phase)
Sound power level33 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1863 × 703 × 598 mm
Operational Weight177 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.