Product data sheetheatpumpdatabase.com

Thermia iTec XTR
Model code: iTec XTR L (400V)
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
3–12 kW
SCOP
5.1
W35
COP
4.75
A7/W35
Max flow temp
75°C
Sound power
75 dB(A)
Refrigerant
R290
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 3–12 kW |
| Max heating output (low temp) | 12 kW at A-10/W35 |
| COP (heating) | 4.75 at A7/W35 |
| SCOP (heating) | 5.1 at W35 |
| Operating range (air) | -25 to 35 °C |
| Heating flow temperature | up to 75 °C |
| Cooling performance | |
| Cooling capacity | 12 kW |
| Electrical, acoustic and physical | |
| Power input | 7.54 kW |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 75 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1018 × 1270 × 530 mm |
| Operational Weight | 247 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.