← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Toshiba Estia R32

Model code: HWT-601HW-E
✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
0.8–7.25 kW
SCOP
4.58
W35
COP
4.8
A7/W35
Max flow temp
55°C
Sound power
66 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

✓ MCS listed

Certificate: 011-1W0467_03; 011-1W0467_04

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity0.8–7.25 kW
Max heating output (low temp)6.42 kW at A2/W35
COP (heating)4.8 at A7/W35
SCOP (heating)4.58 at W35
Operating range (air)-20 to 25 °C
Heating flow temperature20–55 °C
Cooling performance
Cooling capacity5 kW
Max cooling output (high temp)5 kW at A35/W7
EER (cooling)3.3 at A35/W7
Cooling flow temperature7–25 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level66 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)630 × 800 × 300 mm
Operational Weight42 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.