← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Toshiba Estia R32

Model code: HWT-401HW-E
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
0.79–7.25 kW
SCOP
4.53
W35
COP
5.2
A7/W35
Max flow temp
55°C
Sound power
66 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: 011-1W0467_02

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: 011-1W0467_02

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity0.79–7.25 kW
Max heating output (low temp)6.42 kW at A2/W35
COP (heating)5.2 at A7/W35
SCOP (heating)4.53 at W35
Operating range (air)-20 to 25 °C
Heating flow temperature20–55 °C
Cooling performance
Cooling capacity4 kW
Max cooling output (high temp)4 kW at A35/W7
EER (cooling)3.45 at A35/W7
Cooling flow temperature7–25 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level66 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)630 × 800 × 300 mm
Operational Weight42 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.