Trianco Activair HT

Model code: Activair HT 22kW
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
8–22 kW
COP
4.11
Max flow temp
75°C
Sound power
62 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating & cooling
Heating performance
Heating capacity8–22 kW
Max heating output (low temp)22 kW at A7/W35
COP (heating)4.11
Operating range (air)-25 to 45 °C
Heating flow temperature30–75 °C
Cooling performance
Cooling capacity4.2–15 kW
Max cooling output (high temp)15 kW at A35/W7
Electrical, acoustic and physical
Power input9 kW
Electrical supply220-240V (Single Phase)
Sound power level62 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1330 × 1250 × 540 mm
Operational Weight202 kg