← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Vaillant aroTHERM plus

Model code: VWL 125/6 A S2
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
12 kW
COP
4.7
A7/W35
Max flow temp
75°C
Sound power
60 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: KIWA 00044/002 HP

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: KIWA 00044/002 HP

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating & cooling
Heating performance
Heating capacity12 kW
COP (heating)4.7 at A7/W35
Heating flow temperature10–75 °C
Cooling performance
Cooling capacity10.8 kW
EER (cooling)3.5 at A35/W7
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level60 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1565 × 1100 × 490 mm

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.