← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Vaillant aroTHERM plus

Model code: VWL 35/6 A S2
✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
3.5 kW
COP
5.2
A7/W35
Max flow temp
75°C
Sound power
54 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

✓ MCS listed

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating & cooling
Heating performance
Heating capacity3.5 kW
COP (heating)5.2 at A7/W35
Heating flow temperature10–75 °C
Cooling performance
Cooling capacity4.5 kW
EER (cooling)3.4 at A35/W7
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level54 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)965 × 1100 × 490 mm

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.