← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Vaillant aroTHERM Split

Model code: aroTHERM split 3.5kW VWL 35/5 AS 230V S2 + VWL 57/5 IS
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating only
Heating capacity
4 kW
SCOP
4.88
W35
COP
5
A7/W35
Max flow temp
55°C
Sound power
53 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: KIWA 00016/013 HP

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: KIWA 00016/013 HP

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR410A
ModeHeating only
Heating performance
Heating capacity4 kW
Max heating output (low temp)3.7 kW at A-5/W35
COP (heating)5 at A7/W35
SCOP (heating)4.88 at W35
Operating range (air)from -20 °C
Heating flow temperatureup to 55 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level53 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)765 × 1100 × 450 mm
Operational Weight82 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.