← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Vaillant flexoTHERM exclusive

Model code: VWF 117/4 + VWA 11/4 SA
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating only
Heating capacity
12.14 kW
SCOP
4.1
W35
COP
4.63
A7/W35
Max flow temp
65°C
Sound power
44.4 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: KIWA 00023/010 HP

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: KIWA 00023/010 HP

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR410A
ModeHeating only
Heating performance
Heating capacity12.14 kW
Max heating output (low temp)12.14 kW at A7/W55
COP (heating)4.63 at A7/W35
SCOP (heating)4.1 at W35
Heating flow temperatureup to 65 °C
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level44.4 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1183 × 595 × 600 mm
Operational Weight168 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.