← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Viessmann Vitocal 100-A

Model code: Vitocal 100-A AWO-M-AC-AF 101.A16
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Viessmann Vitocal 100-A
Heating capacity
7.36–17.6 kW
SCOP
4.5
W35
COP
4.67
A7/W35
Max flow temp
60°C
Sound power
68 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: ICIM-PDC-000088-00-00

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: ICIM-PDC-000088-00-00

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity7.36–17.6 kW
Max heating output (low temp)17.03 kW at A7/W45
COP (heating)4.67 at A7/W35
SCOP (heating)4.5 at W35
Heating flow temperatureup to 60 °C
Cooling performance
Cooling capacity13.8 kW
Max cooling output (high temp)14.49 kW at A35/W7
EER (cooling)3.15 at A35/W7
SEER (cooling)4.8 at W7
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level68 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1409 × 1044 × 448 mm
Operational Weight126 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.