Viessmann Vitocal 350-A (outdoor installation)

Model code: AWHO 351.A14
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating only
Heating capacity
14.5 kW
SCOP
3.65
W35
COP
3.5
A2/W35
Max flow temp
65°C
Sound power
59 dB(A)
Refrigerant
R407C

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: BSI KM 554512/04/5

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: BSI KM 554512/04/5

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR407C
ModeHeating only
Heating performance
Heating capacity14.5 kW
Max heating output (low temp)14.5 kW at A2/W35
COP (heating)3.5 at A2/W35
SCOP (heating)3.65 at W35
Operating range (air)-20 to 35 °C
Heating flow temperatureup to 65 °C
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level59 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1885 × 1530 × 1265 mm
Operational Weight335 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.