Product data sheetheatpumpdatabase.com

Global Energy Systems Caernarfon
Model code: CAER410MOD1
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating only

Heating capacity
8–14.5 kW
SCOP
4.11
W35
COP
3
A-3/W35
Max flow temp
65°C
Sound power
61.5 dB(A)
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: MCS HP0010/04
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
✓ MCS listed
Certificate: MCS HP0010/04
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Mode | Heating only |
| Heating performance | |
| Heating capacity | 8–14.5 kW |
| Max heating output (low temp) | 13.7 kW at A-3/W35 |
| COP (heating) | 3 at A-3/W35 |
| SCOP (heating) | 4.11 at W35 |
| Operating range (air) | -20 to 30 °C |
| Heating flow temperature | up to 65 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 61.5 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1818 × 1002 × 732 mm |
| Operational Weight | 230 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.