Product data sheetheatpumpdatabase.com

Ideal Heating HP290 4.5kW
Model code: 241486
✓ MCS listedAir Source (ASHP)ResidentialHeating only

Heating capacity
4.6 kW
SCOP
5.07
W35
COP
5.15
A7/W35
Max flow temp
75°C
Sound power
56 dB(A)
Refrigerant
R290
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
✓ MCS listed
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating only |
| Heating performance | |
| Heating capacity | 4.6 kW |
| Max heating output (low temp) | 4.6 kW at A7/W55 |
| COP (heating) | 5.15 at A7/W35 |
| SCOP (heating) | 5.07 at W35 |
| Operating range (air) | -24 to 46 °C |
| Heating flow temperature | up to 75 °C |
| Electrical, acoustic and physical | |
| Power input | 0.87 kW |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 56 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 717 × 1299 × 426 mm |
| Operational Weight | 90 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.