← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Ochsner AIR MILAN 307 C11B CM1

Model code: 50286822-SET02
Air Source (ASHP)ResidentialHeating and Cooling
Heating capacity
5.8 kW
SCOP
5.1
W35
COP
5.1
A7/W35
Max flow temp
70°C
Sound power
55 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating and Cooling
Heating performance
Heating capacity5.8 kW
Max heating output (low temp)5 kW at A-7/W34
COP (heating)5.1 at A7/W35
SCOP (heating)5.1 at W35
Operating range (air)-25 to 46 °C
Heating flow temperature15–70 °C
Cooling performance
Cooling capacity5 kW
Max cooling output (high temp)3.9 kW at A36/W7
EER (cooling)3.91 at A35/W18
SEER (cooling)4.2 at W7
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level55 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)850 × 998 × 549 mm
Operational Weight86 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.