Buy me a coffee
Ochsner logo

Ochsner AIR MILAN 307 C11B CM1

Specifications and technical data

Air Source (ASHP)ResidentialR2905.8 kW
ManufacturerOchsner
ModelAIR MILAN 307 C11B CM1
Model code50286822-SET02
Heat pump typeAir Source (ASHP) All Air Source heat pumps →
ApplicationResidential All Residential heat pumps →
RefrigerantR290 All R290 heat pumps →
ModeHeating and Cooling
Heating capacity5.8 kW
Max heating output (low temp)5 kW at A-7/W34
COP (heating)5.1 at A7/W35
SCOP (heating)5.1 at W35
Operating range (air)-25 to 46 °C
Heating flow temperature15–70 °C
Electrical supply220-240V (Single Phase)
Cooling capacity5 kW
Max cooling output (high temp)3.9 kW at A36/W7
EER (cooling)3.91 at A35/W18
SEER (cooling)4.2 at W7
Dimensions (H×W×D)850 × 998 × 549 mm
Operational Weight86 kg
Sound power level55 dB(A) (Sound Power LW(A))
Data added2026-07-29
Data sourceManufacturer datasheet
VerificationVerified by a human

Free data sheet (PDF) →

Check noise at a neighbour’s window (MCS 020 a) →

View manufacturer page →

Inverter monoblock ASHP with natural refrigerant R290 (propane). 5kW single-phase outdoor unit. CM1 wall-mounted indoor control module only (351×485×131mm) — no integrated tanks. OTS controller. Max flow 70°C. External heater and DHW storage required.

✎ Suggest a correction to this data

Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.

Reviews & further reading

Alternatives to consider

Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.

More from Ochsner

Other Air Source (ASHP) heat pumps

Compare with other products

Open the interactive database →

The Ochsner name and logo are trademarks of their respective owner and are used here for identification purposes only.