Ferroli OMNIA ST heat pump range
7 models compared side by side
The Ferroli OMNIA ST range has 7 models from 4.3 to 15.9 kW: air source heat pumps using R32. Published SCOP is 4.62–5.21 (W35). Maximum flow temperature is 65°C. Sound power is 55–69 dB(A). UK retail prices start from £4,923.93 (unit only, ex-install). 7 of 7 models are on Ofgem’s Boiler Upgrade Scheme eligibility list.
All Ferroli OMNIA ST models
| Model | Product code | Capacity | SCOP (W35) | COP (A7/W35) | Max flow | Sound power | Price (unit) | BUS |
|---|---|---|---|---|---|---|---|---|
| OMNIA ST 3.2 4 | 0XHT4SWA | 4.3 kW | 4.85 | 5.1 | 65°C | 55 dB(A) | ✓ | |
| OMNIA ST 3.2 6 | 0XHT6SWA | 6.35 kW | 4.95 | 4.95 | 65°C | 58 dB(A) | ✓ | |
| OMNIA ST 3.2 8 | 0XHT8SWA | 8.4 kW | 5.21 | 5.15 | 65°C | 59 dB(A) | £4,923.93–£6,305.43 | ✓ |
| OMNIA ST 3.2 10 | 0XHTASWA | 10 kW | 5.19 | 4.95 | 65°C | 60 dB(A) | ✓ | |
| OMNIA ST 3.2 12 | 0XHTCSWA | 12.1 kW | 4.81 | 4.95 | 65°C | 65 dB(A) | £6,532.91–£8,348.06 | ✓ |
| OMNIA ST 3.2 14 | 0XHTESWA | 14.5 kW | 4.72 | 4.6 | 65°C | 65 dB(A) | ✓ | |
| OMNIA ST 3.2 16 | 0XHTGSWA | 15.9 kW | 4.62 | 4.5 | 65°C | 69 dB(A) | £7,162.51–£9,147.34 | ✓ |
Compare these in the interactive database →
Frequently asked questions
What sizes does the Ferroli OMNIA ST come in?
The database lists 7 Ferroli OMNIA ST models: 4.3 kW, 6.35 kW, 8.4 kW, 10 kW, 12.1 kW, 14.5 kW, 15.9 kW.
Which Ferroli OMNIA ST model is the most efficient?
On published data, the Ferroli OMNIA ST 3.2 8 has the highest SCOP in the range at 5.21 (W35). Smaller sizes often score higher on SCOP than larger ones in the same range.
Which Ferroli OMNIA ST model is the quietest?
The Ferroli OMNIA ST 3.2 4 has the lowest published sound power in the range at 55 dB(A). Use the noise calculator to check it against the MCS 020 a) 37 dB limit.
Is the Ferroli OMNIA ST eligible for the Boiler Upgrade Scheme?
7 of 7 Ferroli OMNIA ST models are on Ofgem’s BUS Product Eligibility List. The £7,500 grant also needs an MCS-certified installer. See the funding guide.
Which size Ferroli OMNIA ST do I need?
Size depends on your home’s heat loss, not floor area alone. A typical 3-bed UK home needs around 6–9 kW. Use the heat pump size calculator for an estimate, and always have an MCS installer do a room-by-room heat loss survey.
Other Ferroli ranges
All Ferroli heat pumps → · All heat pump manufacturers →