Buy me a coffee
Toshiba logo

Toshiba Estia HI POWER heat pump range

5 models compared side by side

The Toshiba Estia HI POWER range has 5 models from 11.74 to 14.6 kW: air source heat pumps using R410A. Published SCOP is 4–4.4 (W35). Maximum flow temperature is 60°C. Sound power is 64–68 dB(A).

All Toshiba Estia HI POWER models

ModelProduct codeCapacitySCOP (W35)COP (A7/W35)Max flowSound power
Estia HI POWER (11.74 kW)HWS-P805HR-E11.74 kW44.7660°C64 dB(A)
Estia HI POWER (11.96 kW)HWS-P1105HR-E11.96 kW4.8860°C66 dB(A)
Estia HI POWER (12.13 kW)HWS-P805H8R-E12.13 kW4.34.6860°C66 dB(A)
Estia HI POWER (12.88 kW)HWS-P1105H8R-E12.88 kW4.44.860°C64 dB(A)
Estia HI POWER (14.6 kW)HWS-P1405H8R-E14.6 kW4.44.4460°C68 dB(A)

Compare these in the interactive database →

Frequently asked questions

What sizes does the Toshiba Estia HI POWER come in?

The database lists 5 Toshiba Estia HI POWER models: 11.74 kW, 11.96 kW, 12.13 kW, 12.88 kW, 14.6 kW.

Which Toshiba Estia HI POWER model is the most efficient?

On published data, the Toshiba Estia HI POWER has the highest SCOP in the range at 4.4 (W35). Smaller sizes often score higher on SCOP than larger ones in the same range.

Which Toshiba Estia HI POWER model is the quietest?

The Toshiba Estia HI POWER has the lowest published sound power in the range at 64 dB(A). Use the noise calculator to check it against the MCS 020 a) 37 dB limit.

Which size Toshiba Estia HI POWER do I need?

Size depends on your home’s heat loss, not floor area alone. A typical 3-bed UK home needs around 6–9 kW. Use the heat pump size calculator for an estimate, and always have an MCS installer do a room-by-room heat loss survey.

Other Toshiba ranges

All Toshiba heat pumps → · All heat pump manufacturers →

The Toshiba name and logo are trademarks of their respective owner and are used here for identification purposes only.