Ideal Heating HP290 heat pump range
6 models compared side by side
The Ideal Heating HP290 range has 6 models from 4.6 to 15 kW: air source heat pumps using R290. Published SCOP is 4.59–5.07 (W35). Maximum flow temperature is 75°C. Sound power is 56–69 dB(A). UK retail prices start from £2,300 (unit only, ex-install). 1 of 6 models is on Ofgem’s Boiler Upgrade Scheme eligibility list.
All Ideal Heating HP290 models
| Model | Product code | Capacity | SCOP (W35) | COP (A7/W35) | Max flow | Sound power | Price (unit) | BUS |
|---|---|---|---|---|---|---|---|---|
| HP290 4.5kW | 241486 | 4.6 kW | 5.07 | 5.14 | 75°C | 56 dB(A) | £2,300–£2,878.99 | |
| HP290 6kW | 241487 | 6.2 kW | 4.89 | 4.9 | 75°C | 58 dB(A) | £2,580–£3,049.88 | |
| HP290 8kW | 241488 | 9.5 kW | 5.07 | 4.7 | 75°C | 61 dB(A) | £2,998–£3,402.50 | |
| HP290 10kW | 241489 | 12 kW | 4.67 | 4.8 | 75°C | 65 dB(A) | £3,328–£3,967.37 | ✓ |
| HP290 12kW | 241490 | 14 kW | 4.63 | 4.5 | 75°C | 65 dB(A) | £3,847.52–£4,355.45 | |
| HP290 14kW | 241491 | 15 kW | 4.59 | 4.4 | 75°C | 69 dB(A) | £4,080–£4,482.36 |
Compare these in the interactive database →
Frequently asked questions
What sizes does the Ideal Heating HP290 come in?
The database lists 6 Ideal Heating HP290 models: 4.6 kW, 6.2 kW, 9.5 kW, 12 kW, 14 kW, 15 kW.
Which Ideal Heating HP290 model is the most efficient?
On published data, the Ideal Heating HP290 4.5kW has the highest SCOP in the range at 5.07 (W35). Smaller sizes often score higher on SCOP than larger ones in the same range.
Which Ideal Heating HP290 model is the quietest?
The Ideal Heating HP290 4.5kW has the lowest published sound power in the range at 56 dB(A). Use the noise calculator to check it against the MCS 020 a) 37 dB limit.
Is the Ideal Heating HP290 eligible for the Boiler Upgrade Scheme?
1 of 6 Ideal Heating HP290 models is on Ofgem’s BUS Product Eligibility List. The £7,500 grant also needs an MCS-certified installer. See the funding guide.
Which size Ideal Heating HP290 do I need?
Size depends on your home’s heat loss, not floor area alone. A typical 3-bed UK home needs around 6–9 kW. Use the heat pump size calculator for an estimate, and always have an MCS installer do a room-by-room heat loss survey.
Other Ideal Heating ranges
All Ideal Heating heat pumps → · All heat pump manufacturers →
The Ideal Heating name and logo are trademarks of their respective owner and are used here for identification purposes only.