Nibe F1245 (10.03 kW)
Specifications and technical data
✓ BUS eligibleGround Source (GSHP)ResidentialR407C10.03 kW
| Manufacturer | Nibe |
|---|---|
| Model | F1245 |
| Model code | F1245-10 |
| Heat pump type | Ground Source (GSHP) All Ground Source heat pumps → |
| Application | Residential All Residential heat pumps → |
| Refrigerant | R407C All R407C heat pumps → |
| Mode | Heating only |
| Heating capacity | 10.03 kW |
| Max heating output (low temp) | 9.55 kW at B0/W45 |
| COP (heating) | 4.4 at B0/W35 |
| SCOP (heating) | 4.5 at W35 |
| Operating range (air) | -8 to 30 °C |
| Heating flow temperature | 15–65 °C |
| Electrical supply | 380-415V (Three Phase) |
| Dimensions (H×W×D) | 1800 × 600 × 620 mm |
| Operational Weight | 245 kg |
| Sound power level | 42 dB(A) (Sound Power LW(A)) |
| Data added | 2026-09-14 |
| Data source | Manufacturer installer manual (Nibe) |
| Verification | Verified by a human |
| Boiler Upgrade Scheme | ✓ BUS eligible — Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026). Grant also needs an MCS-certified installer and a qualifying system design. Funding guide |
| PEL certificate no. | 012-042 |
Nibe F1245-10 ground source heat pump with an integrated water heater. Brine-to-water, 400 V three-phase. Heating capacity 10.03 kW at B0/W35 to EN 14511. SCOP 4.5 at 35 °C average climate to EN 14825.
Where to buy (UK)
| UK Supplier | Baxter Heat Pumps |
|---|---|
| UK Supplier | IMS Heat Pumps |
✎ Suggest a correction to this data
Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.
Alternatives to consider
Three Ground Source (GSHP) heat pumps from other manufacturers closest in capacity to this one.
Legend
Thermia · Legend 10
- Capacity
- 9.81 kW
- SCOP
- 5.24 (W35)
- Sound power
- 41 dB(A)
- Refrigerant
- R452B
GMSW
Ochsner · GMSW 10 plus VX
- Capacity
- 10.3 kW
- SCOP
- 4.62 (W35)
- Sound power
- 43 dB(A)
- Refrigerant
- R407C
EcoHeat 400 408 (400V)
CTC · 586610002
- Capacity
- 10.65 kW
- SCOP
- 4.2 (W35)
- Sound power
- 46 dB(A)
- Refrigerant
- R407C
More from Nibe
F2050
ASHP · 5.55 kW · SCOP 5.08 · BUS eligible
F2050
ASHP · 7.18 kW · SCOP 4.59 · BUS eligible
F2050
ASHP · 6.61 kW · SCOP 4.87 · BUS eligible
F2050
ASHP · 10.5 kW · SCOP 4.58 · BUS eligible
S2125
ASHP · 4.72 kW · SCOP 5.33 · BUS eligible
S2125
ASHP · 7.23 kW · SCOP 5 · BUS eligible
S2125
ASHP · 10.31 kW · SCOP 5.33 · BUS eligible
S2125
ASHP · 12.03 kW · SCOP 5.3 · BUS eligible
Other Ground Source (GSHP) heat pumps
WZSV
GSHP · 0.77–6 kW
WZSV
GSHP · 3.32 kW · BUS eligible
WZSV
GSHP · 4 kW · BUS eligible
WZSV
GSHP · 5.06 kW · BUS eligible
WZS
GSHP · 4.7 kW · BUS eligible
WZS
GSHP · 7.7 kW
Compare with other products
Open the interactive database →
The Nibe name and logo are trademarks of their respective owner and are used here for identification purposes only.