Buy me a coffee
Ochsner logo

Ochsner AIR 7 C11A

Specifications and technical data

Air Source (ASHP)CommercialR407C6.4 kW
ManufacturerOchsner
ModelAIR 7 C11A
Model code287010
Heat pump typeAir Source (ASHP) All Air Source heat pumps →
ApplicationCommercial All Commercial heat pumps →
RefrigerantR407C All R407C heat pumps →
ModeHeating and Cooling
Heating capacity6.4 kW
Max heating output (low temp)4.1 kW at A-7/W35
COP (heating)4.8 at A7/W35
SCOP (heating)4.3 at W35
Operating range (air)-22 to 40 °C
Heating flow temperatureup to 65 °C
Electrical supply380-415V (Three Phase)
Cooling capacity4.4 kW
Max cooling output (high temp)3.1 kW at A35/W7
EER (cooling)3.3 at A30/W18
Dimensions (H×W×D)1080 × 1290 × 960 mm
Operational Weight93 kg
Sound power level48 dB(A) (Sound Power LW(A))
Data added2026-07-28
Data sourceManufacturer datasheet
VerificationVerified by a human

Free data sheet (PDF) →

Check noise at a neighbour’s window (MCS 020 a) →

View manufacturer page →

Ochsner AIR 7 C11A high efficiency air/water heat pump with horizontal split evaporator (VHS-M 5). Order number 287010. M2 Series indoor unit (1285×600×681mm, 114kg). R407C refrigerant, scroll compressor, 3-phase 400V. Max flow temperature 65°C. A10/W35: 6.80kW COP 5.10. A2/W35: 5.40kW COP 4.10. A-7/W35: 4.10kW COP 3.20. A2/W50: 4.70kW COP 2.70. A2/W60: 4.30kW COP 2.20. Cooling A30/W18: 4.40kW EER 3.30. SCOP 55°C (mean): 3.17.

✎ Suggest a correction to this data

Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.

Alternatives to consider

Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.

More from Ochsner

Other Air Source (ASHP) heat pumps

Compare with other products

Open the interactive database →

The Ochsner name and logo are trademarks of their respective owner and are used here for identification purposes only.