Heat PumpDatabase
Ochsner logo

Ochsner AIR MILAN 1016 C11B CM1

Specifications and technical data

Air Source (ASHP)ResidentialR2904.4–12 kW
ManufacturerOchsner
ModelAIR MILAN 1016 C11B CM1
Model code50286812-SET02
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating and Cooling
Heating capacity4.4–12 kW
Max heating output (low temp)12 kW at A-7/W34
COP (heating)4.8 at A7/W35
SCOP (heating)4.9 at W35
Operating range (air)-25 to 46 °C
Heating flow temperatureup to 70 °C
Electrical supply220-240V (Single Phase)
Cooling capacity12 kW
Max cooling output (high temp)12 kW at A35/W18
EER (cooling)4 at A35/W18
SEER (cooling)4.8 at W18
Dimensions (H×W×D)1018 × 1270 × 757 mm
Operational Weight140 kg
Sound power level59 dB(A) (Sound Power LW(A))
Data added2026-07-29
Data sourceManufacturer datasheet

View manufacturer page →

Inverter monoblock ASHP with natural refrigerant R290 (propane). 12kW single-phase outdoor unit. CM1 wall-mounted indoor control module only — no integrated tanks. OTS controller. Max flow 70°C. External heater and DHW storage required.

○ Awaiting verification

✎ Suggest a correction to this data

Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.

More from Ochsner

Other Air Source (ASHP) heat pumps

Compare with other products

Open the interactive database →