Alpha Innotec logo

Alpha Innotec LW series (10.1–21.2 kW)

Specifications and technical data

✓ BUS eligibleAir Source (ASHP)ResidentialR407C10.1–21.2 kW
ManufacturerAlpha Innotec
ModelLW series
Model codeLW 180 (L)
Heat pump typeAir Source (ASHP) All Air Source heat pumps →
ApplicationResidential All Residential heat pumps →
RefrigerantR407C All R407C heat pumps →
ModeHeating only
Heating capacity10.1–21.2 kW
Max heating output (low temp)14.1 kW at A-7/W35
COP (heating)3.9 at A7/W35
Operating range (air)-20 to 35 °C
Heating flow temperature20–50 °C
Electrical supply380-415V (Three Phase)
Dimensions (H×W×D)1780 × 1115 × 911 mm
Operational Weight420 kg
Sound power level57 dB(A) (Sound Power LW(A))
Data added2026-09-21
Data sourceManufacturer documentation (Alpha Innotec)
VerificationVerified by a human
Boiler Upgrade Scheme✓ BUS eligible — Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026). Grant also needs an MCS-certified installer and a qualifying system design. Funding guide
PEL certificate no.041-K001-39 b

Free data sheet (PDF) →

Check noise at a neighbour’s window (MCS 020 a) →

Alpha Innotec LW 180 (L) air-to-water heat pump for indoor installation with ducted air intake and discharge, R407C, two-compressor. Rated 19.6 kW at A7/W35 with a COP of 3.9 to EN 14511, or 10.1 kW at COP 4.2 on one compressor. Heating flow up to 50 °C, air from -20 to 35 °C. Three-phase supply.

✎ Suggest a correction to this data

Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.

Alternatives to consider

Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.

More from Alpha Innotec

Other Air Source (ASHP) heat pumps

Compare with other products

Open the interactive database →

The Alpha Innotec name and logo are trademarks of their respective owner and are used here for identification purposes only.