Alpha Innotec LWDV
Specifications and technical data
Also known as: LWDV 91-1/3-HDV 9-1/3, LWDV 91-1/3-HDV 12-3, LWDV 91-1/3-HSDV 9M1/3, LWDV 91-1/3-HSDV 12M3, LWDV-91-1/3-HSDV 12M, LWDV-91-1/3-HSDV9 M1/3, LWDV 91-1/3-HDV9-1/3, LWDV 91-1/3-HDV 12-3
| Manufacturer | Alpha Innotec |
|---|---|
| Model | LWDV |
| Model code | LWDV 91-1/3 |
| Heat pump type | Air Source (ASHP) All Air Source heat pumps → |
| Application | Residential All Residential heat pumps → |
| Refrigerant | R290 All R290 heat pumps → |
| Mode | Heating only |
| Heating capacity | 2.74–8.2 kW |
| Max heating output (low temp) | 8.11 kW at A-7/W35 |
| COP (heating) | 5.41 at A7/W35 |
| Operating range (air) | -22 to 35 °C |
| Heating flow temperature | 20–70 °C |
| Electrical supply | 220-240V (Single Phase) |
| Dimensions (H×W×D) | 1320 × 930 × 510 mm |
| Operational Weight | 141 kg |
| Sound power level | 59 dB(A) (Sound Power LW(A)) |
| Data added | 2026-09-21 |
| Data source | Manufacturer documentation (Alpha Innotec) |
| Verification | Verified by a human |
| Boiler Upgrade Scheme | ✓ BUS eligible — Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026). Grant also needs an MCS-certified installer and a qualifying system design. Funding guide |
| PEL certificate no. | 041-K001-24 a |
Check noise at a neighbour’s window (MCS 020 a) →
Alpha Innotec LWDV 91-1/3 air-to-water monobloc for outdoor installation, fully modulating, natural R290 refrigerant, paired with an HDV hydraulic module or HSDV hydraulic station indoors. Declared 2.77 kW at A7/W35 at part load with a COP of 5.41 to EN 14511, modulating from 2.74 to 8.20 kW at that point, and 8.11 kW at A-7/W35 at full load. Heating flow up to 70 °C, air from -22 to 35 °C. Available single- or three-phase.
✎ Suggest a correction to this data
Alternatives to consider
Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.
- Capacity
- 8.2 kW
- SCOP
- 5.16 (W55)
- Sound power
- 55 dB(A)
- Refrigerant
- R32
- Price
- £2,719–£3,485.83
- Capacity
- 8.2 kW
- SCOP
- 4.49 (W35)
- Sound power
- 58 dB(A)
- Refrigerant
- R290
- Capacity
- 8.38 kW
- SCOP
- 4.92 (W35)
- Sound power
- 58 dB(A)
- Refrigerant
- R290
More from Alpha Innotec
Other Air Source (ASHP) heat pumps
Compare with other products
Open the interactive database →