Ares Renewables logo

Ares Renewables S5 (6 kW)

Specifications and technical data

Also known as: S506V3/S5IU06SV3

✓ BUS eligibleAir Source (ASHP)ResidentialR326 kW
ManufacturerAres Renewables
ModelS5
Model codeS505V3
Heat pump typeAir Source (ASHP) All Air Source heat pumps →
ApplicationResidential All Residential heat pumps →
RefrigerantR32 All R32 heat pumps →
ModeHeating & cooling
Heating capacity6 kW
Max heating output (low temp)6 kW at A7/W55
COP (heating)4.98 at A7/W35
SCOP (heating)4.8 at W35
Operating range (air)-25 to 35 °C
Heating flow temperature15–60 °C
Electrical supply220-240V (Single Phase)
Cooling capacity6 kW
Max cooling output (high temp)6 kW at A35/W7
Cooling flow temperature5–25 °C
EER (cooling)3.05 at A35/W7
Dimensions (H×W×D)765 × 920 × 372 mm
Operational Weight55 kg
Sound power level61 dB(A) (Sound Power LW(A))
Data added2026-10-20
Data sourceAres Power heat pumps catalogue
VerificationVerified by a human
Boiler Upgrade Scheme✓ BUS eligible — Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026). Grant also needs an MCS-certified installer and a qualifying system design. Funding guide
PEL certificate no.24.01.011
MCS certification✓ MCS listed
MCS certificate no.24.01.011

Free data sheet (PDF) →

Check noise at a neighbour’s window (MCS 020 a) →

Ares S5 S506V3 R32 split air-to-water heat pump outdoor unit (with S5IU06SV3 hydro box), 6 kW at A7/W35, flow 15-60 °C, heating and cooling, single-phase.

✎ Suggest a correction to this data

Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.

Alternatives to consider

Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.

More from Ares Renewables

Other Air Source (ASHP) heat pumps

Compare with other products

Open the interactive database →

The Ares Renewables name and logo are trademarks of their respective owner and are used here for identification purposes only.