Daikin Altherma 3 H HT
Specifications and technical data
Air Source (ASHP)ResidentialR3211.57 kW
| Manufacturer | Daikin |
|---|---|
| Model | Altherma 3 H HT |
| Model code | ETBH16E6V + EPRA16DV3 |
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating only |
| Heating capacity | 11.57 kW |
| COP (heating) | 4.86 at A7/W35 |
| SCOP (heating) | 4.51 at W35 |
| Operating range (air) | -28 to 35 °C |
| Heating flow temperature | 18–70 °C |
| Electrical supply | 230V/1P/50Hz |
| Dimensions (H×W×D) | 990 × 1270 × 460 mm |
| Operational Weight | 146 kg |
| Sound power level | 54 dB(A) (Sound power Lw(A)) |
| Data added | 2026-07-07T00:00:00 |
| Data source | Manufacturer Data Sheet |
Notes
Daikin Altherma 3 H HT ETBH16E6V wall-mounted heating-only ASHP with EPRA16DV3 outdoor unit, R32, heating down to -28C.
Indoor dims 840x440x390mm. SCOP at 55C water outlet=3.58 (A++). Also SCOP 4.71/eta186% (35C) & 3.57/eta140% (55C) for 3-phase EPRA16DW1 indoor E9W variant, COP 4.50/3.56, weight 151kg, fuses 16A. 1-phase fuses 32A. Nominal capacity shown at A-2/W55; COP at A7/W35.
Where to buy (UK)
| UK Supplier | The Heat Pump Warehouse |
|---|---|
| UK Supplier | Space Air |
| UK Supplier | City Plumbing |
✓ Verified via Manual Verification data
✎ Suggest a correction to this data
Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.
More from Daikin
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.51
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.57
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.57
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.57
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.51
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.51
Other Air Source (ASHP) heat pumps
Hybrox
ASHP · 2.05–5.5 kW
Hybrox
ASHP · 3.01–8 kW
Hybrox
ASHP · 2.97–10 kW
Hybrox
ASHP · 7.15–18 kW
Hybrox
ASHP · 2.2–13 kW
Hybrox SE
ASHP · 0.83–7.05 kW