Haier HPM 14kW (400V)
Specifications and technical data
Air Source (ASHP)ResidentialR29014 kW
| Manufacturer | Haier |
|---|---|
| Model | HPM 14kW (400V) |
| Model code | HPM14-TND2-H |
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating only |
| Heating capacity | 14 kW |
| COP (heating) | 5.27 at A7/W35 |
| SCOP (heating) | 5.46 at W35 |
| Operating range (air) | -30 to 35 °C |
| Heating flow temperature | 25–85 °C |
| Electrical supply | 380-415V (Three Phase) |
| Dimensions (H×W×D) | 950 × 1300 × 520 mm |
| Sound power level | 54 dB(A) (Sound Power LW(A)) |
| Data added | 2026-06-27 |
| Data source | Manufacturer Data Sheet |
| MCS certification | ✓ MCS listed — eligible for Boiler Upgrade Scheme (MCS-certified install required) |
| MCS certificate no. | MR 50717196 0001/007 |
| MCS listing | View on MCS ↗ |
Haier HPM 14kW (400V) is a 14 kW air source heat pump, using R290 refrigerant.
Where to buy (UK)
| UK Supplier | HVAC-Sanitary |
|---|
✓ Manually verified by Heat Pump Database
✎ Suggest a correction to this data
Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.
More from Haier
HPM 6kW
ASHP · 6 kW · SCOP 5.21
HPM 8kW
ASHP · 8 kW · SCOP 5.25
HPM 10kW
ASHP · 10 kW · SCOP 5.21
HPM 10kW (400V)
ASHP · 10 kW · SCOP 5.21
HPM 12kW
ASHP · 12 kW · SCOP 5.08
HPM 12kW (400V)
ASHP · 12 kW · SCOP 5.08
HPM 16kW (400V)
ASHP · 16 kW · SCOP 5.41
HPM 8kW
ASHP · 8 kW · SCOP 4.95
Other Air Source (ASHP) heat pumps
H-600 CO₂
ASHP · 300–600 kW
H-1200 CO₂
ASHP · 600–1200 kW
H-1800 CO₂
ASHP · 900–1800 kW
H-2600 CO₂
ASHP · 1500–3000 kW
NX-Q-G06
ASHP · 157.5 kW
NX-Q-G06
ASHP · 174.6 kW
Compare with other products
Open the interactive database →
The Haier name and logo are trademarks of their respective owner and are used here for identification purposes only.