Ochsner AIR MILAN 612 C11A T200

Specifications and technical data

Air Source (ASHP)ResidentialR2903.2–8 kW
ManufacturerOchsner
ModelAIR MILAN 612 C11A T200
Model code50286801-SET01
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating and Cooling
Heating capacity3.2–8 kW
Max heating output (low temp)7.5 kW at A-7/W34
COP (heating)4.91 at A7/W35
SCOP (heating)4.85 at W35
Operating range (air)-25 to 46 °C
Heating flow temperatureup to 70 °C
Electrical supply380-415V (Three Phase)
Cooling capacity8 kW
Max cooling output (high temp)8 kW at A35/W18
EER (cooling)3.9 at A35/W18
SEER (cooling)4.3 at W18
Dimensions (H×W×D)850 × 998 × 549 mm
Operational Weight98 kg
Sound power level59 dB(A) (Sound Power LW(A))
Data added2026-07-29
Data sourceManufacturer datasheet

View manufacturer page →

Inverter monoblock ASHP with natural refrigerant R290 (propane). 3-phase outdoor unit. T200 indoor unit includes 168L enamelled steel DHW tank + 100L buffer tank. OTS controller. Max flow 70°C. Built-in 5.8kW electric heater.