Thermia Athena (Athena 18 HC)
Specifications and technical data
Air Source (ASHP)ResidentialR410A7.85–17.5 kW
| Manufacturer | Thermia |
|---|---|
| Model | Athena |
| Model code | Athena 18 HC |
| Heat pump type | Air Source (ASHP) All Air Source heat pumps → |
| Application | Residential All Residential heat pumps → |
| Refrigerant | R410A All R410A heat pumps → |
| Mode | Heating only |
| Heating capacity | 7.85–17.5 kW |
| Max heating output (low temp) | 12.86 kW at A-7/W35 |
| COP (heating) | 5.09 at A7/W35 |
| SCOP (heating) | 4.76 at W35 |
| Operating range (air) | -20 to 37 °C |
| Heating flow temperature | up to 65 °C |
| Power input | 15.9 kW |
| Electrical supply | 380-415V (Three Phase) |
| Dimensions (H×W×D) | 1045 × 1490 × 593 mm |
| Operational Weight | 188 kg |
| Sound power level | 55 dB(A) (Sound Power LW(A)) |
| Data added | 2026-07-06 |
| Data source | Manufacturer Data Sheet |
| Verification | Verified by a human |
Check noise at a neighbour’s window (MCS 020 a) →
Thermia Athena 18 HC is a 17.5 kW air source heat pump, using R410A refrigerant.
✎ Suggest a correction to this data
Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.
Reviews & further reading
- Manufacturer Thermia Athena — Thermia
Alternatives to consider
Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.
Ebac 9kW White + Grey
Ebac · H1D09WG-GB
- Capacity
- 17.5 kW
- SCOP
- 4.84 (W35)
- Sound power
- 64.1 dB(A)
- Refrigerant
- R32
- Price
- ~£3,302
Monobloc
Peak · PEP-M17
- Capacity
- 17.4 kW
- SCOP
- 3.37 (W35)
- Sound power
- 70 dB(A)
- Refrigerant
- R410A
Yutaki S80
Hitachi · Yutaki S80 16kW
- Capacity
- 17.8 kW
- SCOP
- 3.88 (W35)
- Sound power
- 64 dB(A)
- Refrigerant
- R410A + R134A
- Price
- ~£6,540.79
More from Thermia
iTec XTR
ASHP · 1–5 kW · SCOP 5.1
iTec XTR
ASHP · 2–8 kW · SCOP 5.1
iTec XTR
ASHP · 3–12 kW · SCOP 5.1
iTec XTR
ASHP · 3–16 kW · SCOP 5.1
Mega
GSHP · 10–33 kW · SCOP 5.72
Mega
GSHP · 10–33 kW · SCOP 5.72
Mega
GSHP · 11–44 kW · SCOP 5.86
Mega
GSHP · 14–59 kW · SCOP 5.29
Other Air Source (ASHP) heat pumps
H-600 CO₂
ASHP · 300–600 kW
H-1200 CO₂
ASHP · 600–1200 kW
H-1800 CO₂
ASHP · 900–1800 kW
H-2600 CO₂
ASHP · 1500–3000 kW
NX-Q-G06
ASHP · 157.5 kW
NX-Q-G06
ASHP · 174.6 kW
Compare with other products
Open the interactive database →
The Thermia name and logo are trademarks of their respective owner and are used here for identification purposes only.