Daikin Altherma 3 M
Specifications and technical data
Air Source (ASHP)ResidentialR329.37 kW
| Manufacturer | Daikin |
|---|---|
| Model | Altherma 3 M |
| Model code | EBLA09DV3 |
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating & cooling |
| Heating capacity | 9.37 kW |
| COP (heating) | 4.91 at A7/W35 |
| SCOP (heating) | 4.82 at W35 |
| Operating range (air) | -25 to 35 °C |
| Heating flow temperature | 9–60 °C |
| Electrical supply | 230V/1P/50Hz |
| Cooling capacity | 9.35 kW |
| Cooling flow temperature | 5–22 °C |
| EER (cooling) | 3.35 at A35/W7 |
| SEER (cooling) | 5.62 at Not stated |
| Dimensions (H×W×D) | 870 × 1380 × 460 mm |
| Operational Weight | 147 kg |
| Sound power level | 62 dB(A) (Sound power Lw(A)) |
| Data added | 2026-07-07T00:00:00 |
| Data source | Manufacturer Data Sheet |
Notes
Daikin Altherma 3 M EBLA09DV3 monobloc reversible ASHP, R32, 9.37kW nominal heating / 9.35kW cooling.
SCOP 55C=3.44, eta=135% (A++). Cooling power input 2.79kW at EW12/LW7. Cooling ambient range 10~43C. 3-phase EBLA09DW1 variant available.
Where to buy (UK)
| UK Supplier | The Heat Pump Warehouse |
|---|---|
| UK Supplier | Space Air |
| UK Supplier | City Plumbing |
✓ Verified via Manual Verification data
✎ Suggest a correction to this data
Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.
More from Daikin
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.51
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.51
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.57
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.57
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.57
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.51
Other Air Source (ASHP) heat pumps
Hybrox
ASHP · 2.05–5.5 kW
Hybrox
ASHP · 3.01–8 kW
Hybrox
ASHP · 2.97–10 kW
Hybrox
ASHP · 7.15–18 kW
Hybrox
ASHP · 2.2–13 kW
Hybrox SE
ASHP · 0.83–7.05 kW