Daikin Altherma 3 M (EBLA09D3V3U)
Specifications and technical data
Also known as: EBLA09DA3V3U
✓ BUS eligibleAir Source (ASHP)ResidentialR329.37 kW
| Manufacturer | Daikin |
|---|---|
| Model | Altherma 3 M |
| Model code | EBLA09D3V3U |
| Heat pump type | Air Source (ASHP) All Air Source heat pumps → |
| Application | Residential All Residential heat pumps → |
| Refrigerant | R32 All R32 heat pumps → |
| Mode | Heating & cooling |
| Heating capacity | 9.37 kW |
| Max heating output (low temp) | 9 kW at A7/W45 |
| COP (heating) | 4.91 at A7/W35 |
| SCOP (heating) | 4.77 at W35 |
| Operating range (air) | from -25 °C |
| Heating flow temperature | 15–60 °C |
| Electrical supply | 220-240V (Single Phase) |
| Cooling capacity | 9.35 kW |
| Max cooling output (high temp) | 9.35 kW at A35/W7 |
| Cooling flow temperature | 5–22 °C |
| EER (cooling) | 3.35 at A35/W7 |
| Dimensions (H×W×D) | 870 × 1380 × 460 mm |
| Operational Weight | 149 kg |
| Data added | 2026-09-22 |
| Data source | Manufacturer documentation (Daikin) |
| Verification | Verified by a human |
| Boiler Upgrade Scheme | ✓ BUS eligible — Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026). Grant also needs an MCS-certified installer and a qualifying system design. Funding guide |
| PEL certificate no. | 011-1W0423_10 |
Daikin Altherma 3 M EBLA09D3V3U, air-to-water monobloc, R-32. Rated 9.37 kW at A7/W35 with a COP of 4.91 to EN 14511, and 9.00 kW at A7/W45 with a COP of 3.71. SCOP 4.77 at W35. Reversible, 9.35 kW cooling at A35/W7 with an EER of 3.35. Heating flow 15 to 60 C. Single-phase supply.
Where to buy (UK)
| UK Supplier | The Heat Pump Warehouse |
|---|---|
| UK Supplier | Space Air |
| UK Supplier | City Plumbing |
| UK Supplier | The Underfloor Heating Store |
✎ Suggest a correction to this data
Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.
Reviews & further reading
- Manufacturer Daikin Altherma 3 M — Daikin
- Manufacturer Daikin Altherma 3 H MT F — Daikin
- Review Daikin Altherma 3 Review: Is It the Right Heat Pump for Your Home? — Green Reach EnergyCovers the Altherma 3 range generally, including the monobloc (M) variant.
- Review Daikin Altherma 3 Heat Pump Range — Heat Pump HQ
- Review Daikin Altherma 3 Review: Is It the Right Heat Pump for Your Home? — Home Energy Quotes
- Review Daikin Heat Pump Review UK: Altherma Range, COP, Price, Pros and Cons — Home Heat Pump Guide
►NEW Daikin Altherma 3 M R32 Monobloc InstallationYouTube
►Daikin Altherma 3 M R32 MonoblocDaikin Ireland
►Daikin Altherma 3 EPRA + ETVH/X - Connecting water pipingDaikinEurope
►Daikin Altherma MMI Controller - Complete User GuideCB Heating
►Choosing The Perfect Heat Pump: Octopus Cosy 6 Vs Daikin AlthermaJonathan Tracey
►Daikin Altherma 3M / Heat Pump with a redesigned casingInstarom Instalaţii RomâAlternatives to consider
Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.
R290 Hydro Split Set
AXEN · KFS-90W/N7BP
- Capacity
- 9.3 kW
- SCOP
- 5 (W35)
- Refrigerant
- R290
HPA-O 10.2 Trend HC 230V
Stiebel Eltron · 207422
- Capacity
- 9.49 kW
- SCOP
- 4.59 (W35)
- Sound power
- 46 dB(A)
- Refrigerant
- R290
Electa-ECOS-B MHAITI 110
Rhoss
- Capacity
- 9.5 kW
- SCOP
- 3.25 (W55)
- Refrigerant
- R32
More from Daikin
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.57 · BUS eligible
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.57 · BUS eligible
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.57 · BUS eligible
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.51 · BUS eligible
Other Air Source (ASHP) heat pumps
H-600 CO₂
ASHP · 300–600 kW
H-1200 CO₂
ASHP · 600–1200 kW
H-1800 CO₂
ASHP · 900–1800 kW
H-2600 CO₂
ASHP · 1500–3000 kW
NX-Q-G06
ASHP · 157.5 kW
NX-Q-G06
ASHP · 174.6 kW
Compare with other products
Open the interactive database →
The Daikin name and logo are trademarks of their respective owner and are used here for identification purposes only.