Daikin Altherma 3 R (ERLA14D2W1)
Specifications and technical data
Air Source (ASHP)ResidentialR3212.5 kW
| Manufacturer | Daikin |
|---|---|
| Model | Altherma 3 R |
| Model code | ERLA14D2W1 |
| Heat pump type | Air Source (ASHP) All Air Source heat pumps → |
| Application | Residential All Residential heat pumps → |
| Refrigerant | R32 All R32 heat pumps → |
| Mode | Heating & cooling |
| Heating capacity | 12.5 kW |
| Max heating output (low temp) | 12 kW at A7/W35 |
| COP (heating) | 4.87 at A7/W35 |
| SCOP (heating) | 4.68 at W35 |
| Operating range (air) | from -25 °C |
| Heating flow temperature | up to 60 °C |
| Electrical supply | 380-415V (Three Phase) |
| Cooling capacity | 13.3 kW |
| Max cooling output (high temp) | 13.1 kW at A35/W7 |
| EER (cooling) | 3.02 at A35/W7 |
| SEER (cooling) | 5.89 at EN 14825 (flow temp not stated) |
| Dimensions (H×W×D) | 870 × 1100 × 460 mm |
| Operational Weight | 101 kg |
| Sound power level | 62 dB(A) (Sound Power LW(A)) |
| Data added | 2026-09-13 |
| Data source | Manufacturer specification table (Daikin UK) |
| Verification | Verified by a human |
Check noise at a neighbour’s window (MCS 020 a) →
Daikin Altherma 3 R ERLA14D2W1: 12.5 kW, R32, three-phase supply. Split-system outdoor unit for the Daikin Altherma 3 R, medium temperature range, capacity class 14 kW. Pairs with a separate indoor hydrobox or integrated cylinder unit, which is where the rated output and efficiency are declared. R-32 refrigerant, 3.8 kg factory charge. Leaving water up to 60 °C, down to -7 °C ambient.
Where to buy (UK)
| UK Supplier | The Heat Pump Warehouse |
|---|---|
| UK Supplier | Space Air |
| UK Supplier | City Plumbing |
| UK Supplier | The Underfloor Heating Store |
✎ Suggest a correction to this data
Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.
Alternatives to consider
Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.
iTec E
Thermia · iTec E 12
- Capacity
- 3.4–12.5 kW
- SCOP
- 4.69 (W35)
- Sound power
- 64 dB(A)
- Refrigerant
- R32
R290 Series
SolaX · STU1-C12R290
- Capacity
- 12.5 kW
- SCOP
- 5.07 (W35)
- Sound power
- 51 dB(A)
- Refrigerant
- R290
Hydrolution EZY
Mitsubishi Heavy Industries · FDCM140VNX-P
- Capacity
- 12.5 kW
- SCOP
- 4.68 (W35)
- Sound power
- 57 dB(A)
- Refrigerant
- R290
More from Daikin
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.57 · BUS eligible
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.57 · BUS eligible
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.57 · BUS eligible
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.51 · BUS eligible
Other Air Source (ASHP) heat pumps
H-600 CO₂
ASHP · 300–600 kW
H-1200 CO₂
ASHP · 600–1200 kW
H-1800 CO₂
ASHP · 900–1800 kW
H-2600 CO₂
ASHP · 1500–3000 kW
NX-Q-G06
ASHP · 157.5 kW
NX-Q-G06
ASHP · 174.6 kW
Compare with other products
Open the interactive database →
The Daikin name and logo are trademarks of their respective owner and are used here for identification purposes only.