Daikin Altherma monobloc (EBLQ011CA3V3)
Specifications and technical data
✓ BUS eligibleAir Source (ASHP)ResidentialR410A11.2 kW
| Manufacturer | Daikin |
|---|---|
| Model | Altherma monobloc |
| Model code | EBLQ011CA3V3 |
| Heat pump type | Air Source (ASHP) All Air Source heat pumps → |
| Application | Residential All Residential heat pumps → |
| Refrigerant | R410A All R410A heat pumps → |
| Mode | Heating & cooling |
| Heating capacity | 11.2 kW |
| Max heating output (low temp) | 11.2 kW at A7/W35 |
| COP (heating) | 4.61 at A7/W35 |
| SCOP (heating) | 4.28 at W35 |
| Operating range (air) | from -25 °C |
| Heating flow temperature | 25–55 °C |
| Electrical supply | 220-240V (Single Phase) |
| Cooling capacity | 11.6 kW |
| Max cooling output (high temp) | 11.6 kW at A35/W7 |
| Cooling flow temperature | 5–22 °C |
| EER (cooling) | 2.28 at A35/W7 |
| Dimensions (H×W×D) | 1348 × 1160 × 380 mm |
| Operational Weight | 157 kg |
| Sound power level | 64 dB(A) (Sound Power LW(A)) |
| Data added | 2026-09-22 |
| Data source | Manufacturer documentation (Daikin) |
| Verification | Verified by a human |
| Boiler Upgrade Scheme | ✓ BUS eligible — Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026). Grant also needs an MCS-certified installer and a qualifying system design. Funding guide |
| PEL certificate no. | 011-1W0259_11 |
Check noise at a neighbour’s window (MCS 020 a) →
Daikin Altherma monobloc EBLQ011CA3V3, air-to-water outdoor unit with integrated hydraulics, R-410A. Rated 11.2 kW at A7/W35 with a COP of 4.61 to EN 14511, and 11.0 kW at A7/W45 with a COP of 3.55. SCOP 4.28 at W35. Reversible, 11.6 kW cooling at A35/W7 with an EER of 2.28. Heating flow 25 to 55 C, domestic hot water to 80 C. Supply 1~ 230 V.
Where to buy (UK)
| UK Supplier | The Heat Pump Warehouse |
|---|---|
| UK Supplier | Space Air |
| UK Supplier | City Plumbing |
| UK Supplier | The Underfloor Heating Store |
✎ Suggest a correction to this data
Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.
Alternatives to consider
Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.
010
Sime · SHP-M-PRO-010
- Capacity
- 11.2 kW
- SCOP
- 5.12 (W35)
- Sound power
- 65 dB(A)
- Refrigerant
- R32
AIR BASIC 211 C11B G1-1
Ochsner · 285610
- Capacity
- 1.9–11.2 kW
- SCOP
- 4.04 (W35)
- Sound power
- 62 dB(A)
- Refrigerant
- R410A
Estia
Toshiba · HWS-1105H-E
- Capacity
- 11.2 kW
- SCOP
- 4.15 (W35)
- Sound power
- 64 dB(A)
- Refrigerant
- R410A
More from Daikin
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.57 · BUS eligible
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.57 · BUS eligible
Altherma 3 H HT
ASHP · 12.11 kW · SCOP 4.57 · BUS eligible
Altherma 3 H HT
ASHP · 10.17 kW · SCOP 4.51 · BUS eligible
Altherma 3 H HT
ASHP · 11.57 kW · SCOP 4.51 · BUS eligible
Other Air Source (ASHP) heat pumps
H-600 CO₂
ASHP · 300–600 kW
H-1200 CO₂
ASHP · 600–1200 kW
H-1800 CO₂
ASHP · 900–1800 kW
H-2600 CO₂
ASHP · 1500–3000 kW
NX-Q-G06
ASHP · 157.5 kW
NX-Q-G06
ASHP · 174.6 kW
Compare with other products