Specifications and technical data

Also known as: Ideal Logic Air 5kW, Ideal Logic Air

✓ BUS eligibleAir Source (ASHP)ResidentialR325 kW
ManufacturerIdeal Heating
ModelLogic Air 5kW
Model codeAH750665
Heat pump typeAir Source (ASHP) All Air Source heat pumps →
ApplicationResidential All Residential heat pumps →
RefrigerantR32 All R32 heat pumps →
ModeHeating only
Heating capacity5 kW
Max heating output (low temp)5 kW at A7/W55
COP (heating)5 at A7/W35
SCOP (heating)5.07 at W55
Operating range (air)-24 to 46 °C
Heating flow temperatureup to 55 °C
Power input0.97 kW
Electrical supply220-240V (Single Phase)
Dimensions (H×W×D)798 × 1095 × 518 mm
Operational Weight86 kg
Sound power level52 dB(A) (Sound Power LW(A))
Price (unit only)£2,437–£3,133.22 (checked 28/08/2026)
Data added2026-06-27
Data sourceManufacturer Data Sheet
VerificationVerified by a human
Boiler Upgrade Scheme✓ BUS eligible — Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026). Grant also needs an MCS-certified installer and a qualifying system design. Funding guide
PEL certificate no.KIWA 00027/023 HP
MCS certification✓ MCS listed
MCS certificate no.KIWA 00027/023 HP
MCS listingView on MCS ↗
Real-world performance dataView on HeatpumpMonitor.org ↗

Free data sheet (PDF) →

Check noise at a neighbour’s window (MCS 020 a) →

View manufacturer page →

Ideal Heating Logic Air 5kW is a 5 kW air source heat pump, using R32 refrigerant.

Where to buy (UK)

UK SupplierSecon Renewables
UK SupplierEco Wizard
UK SupplierPlumbing Superstore
UK SupplierMr Central Heating
UK SupplierQuality Heating

✎ Suggest a correction to this data

Data is compiled from manufacturer sources and may contain errors or gaps. Always confirm specifications with the manufacturer before making decisions.

Reviews & further reading

Compatible cylinders & tanks

28 cylinders, buffers and indoor units listed for this heat pump.

ModelTypeVolumeHeat lossH × W × DPrice
Logic Air pre-plumbed 180L buffer, 1 zoneCombi (buffer + DHW)180 L1.176 kWh/24h1907 × 644 × 702 mm~£2,675
Logic Air pre-plumbed 180L buffer, 2 zoneCombi (buffer + DHW)180 L1.176 kWh/24h1907 × 644 × 702 mm~£2,793
Logic Air pre-plumbed 210L buffer, 1 zoneCombi (buffer + DHW)210 L1.32 kWh/24h2095 × 644 × 702 mm~£2,742
Logic Air pre-plumbed 210L buffer, 2 zoneCombi (buffer + DHW)210 L1.32 kWh/24h2095 × 644 × 702 mm~£2,861
Logic Air pre-plumbed 250L buffer, 1 zoneCombi (buffer + DHW)250 L1.488 kWh/24h1908 × 705 × 780 mm~£3,000
Logic Air pre-plumbed 250L buffer, 2 zoneCombi (buffer + DHW)250 L1.488 kWh/24h1908 × 705 × 780 mm~£3,118
Logic Air pre-plumbed 300L buffer, 1 zoneCombi (buffer + DHW)300 L1.632 kWh/24h2128 × 705 × 780 mm~£3,071
Logic Air pre-plumbed 300L buffer, 2 zoneCombi (buffer + DHW)300 L1.632 kWh/24h2128 × 705 × 780 mm~£3,189
Logic Air pre-plumbed 150L 1 zoneUnvented150 L1.056 kWh/24h1196 × 636 × 683 mm~£2,059
Logic Air pre-plumbed 150L 1 zone slimlineUnvented150 L1.2 kWh/24h1598 × 581 × 606 mm~£2,097
Pre-plumbed hot water cylinder 150L slimlineUnvented150 L1.21 kWh/24h1519 × 475 mm
Heat pump cylinder 180LUnvented180 L1.32 kWh/24h1306 × 550 mm~£1,204
Heat pump cylinder slimline 180LUnvented180 L1.608 kWh/24h1791 × 475 mm
Logic Air pre-plumbed 180L 1 zoneUnvented180 L1.176 kWh/24h1384 × 636 × 683 mm~£2,306
Logic Air pre-plumbed 180L 1 zone slimlineUnvented180 L1.392 kWh/24h1870 × 581 × 606 mm~£2,364
Pre-plumbed hot water cylinder 180L slimlineUnvented180 L1.4 kWh/24h1791 × 475 mm~£1,488
Pre-plumbed hot water cylinder 180LUnvented180 L1.18 kWh/24h1306 × 550 mm
Heat pump cylinder 210LUnvented210 L1.488 kWh/24h1494 × 550 mm£1,123–£1,251
Heat pump cylinder slimline 210LUnvented210 L1.776 kWh/24h1963 × 475 mm~£1,242
Logic Air pre-plumbed 210L low loss header, 2 zoneUnvented210 L1.32 kWh/24h1572 × 704 × 686 mm~£2,375
Logic Air pre-plumbed 210L low loss header, 2 zone slimlineUnvented210 L1.56 kWh/24h2042 × 647 × 620 mm~£2,380
Pre-plumbed hot water cylinder 210LUnvented210 L1.33 kWh/24h1494 × 550 mm
Heat pump cylinder 250LUnvented250 L1.776 kWh/24h1744 × 550 mm
Pre-plumbed hot water cylinder 250LUnvented250 L1.52 kWh/24h1744 × 550 mm~£1,600
Logic Air pre-plumbed 250L low loss header, 2 zoneUnvented250 L1.512 kWh/24h1822 × 704 × 686 mm
Heat pump cylinder 300LUnvented300 L2.064 kWh/24h1990 × 550 mm~£1,171
Pre-plumbed hot water cylinder 300LUnvented300 L1.74 kWh/24h1990 × 550 mm~£1,679
Logic Air pre-plumbed 300L low loss header, 2 zoneUnvented300 L1.728 kWh/24h2068 × 704 × 686 mm

Compare these in Cylinders & Tanks →

Alternatives to consider

Three Air Source (ASHP) heat pumps from other manufacturers closest in capacity to this one.

More from Ideal Heating

Other Air Source (ASHP) heat pumps

Compare with other products

Open the interactive database →

The Ideal Heating name and logo are trademarks of their respective owner and are used here for identification purposes only.